Answers Database
EDIF2NGD: Application Error EDIF2NGD caused an invalid page fault in module EDIF2NGD.exe
Record #2799
Product Family: Software
Product Line: Merged Core
Problem Title:
EDIF2NGD: Application Error EDIF2NGD caused an invalid page fault in
module EDIF2NGD.exe
Problem Description:
Keywords: EDN, EDIF, EDIF2NGD, Workview Office, page fault
Urgency: Standard
This error may occur when trying to process a Viewlogic .edn file in
the M1.3 Design Manager:
EDIF2NGD: Application Error
There's a details button. When pressed you get the following:
EDIF2NGD caused an invalid page fault in module EDIF2NGD.exe@00147:00404A58
Solution 1:
One possible reason for getting this application error is that the
EDIF was not exported correctly from the Viewlogic environment.
Please follow these steps to export an EDIF (.edn) file for use with
M1.3:
Within Workview Office ViewDraw:
Tools -> Write Xilinx EDIF
If you do not have this menu selection, please see
(Xilinx Solution 1985).
Powerview users will have to use the EDIF netlister (remember to
select Level=Xilinx) or the command line (edifneto -l xilinx <design>).
These methods will work for Workview Office users as well.
End of Record #2799