Answers Database
FATAL_ERROR:basbd:basbdbool.c:393:1.5 - Signal unassigned to variable encountered. Process will terminate. Please call Xilinx support.
Record #2863
Product Family: Software
Product Line: Merged Core
Problem Title:
FATAL_ERROR:basbd:basbdbool.c:393:1.5 - Signal unassigned to variable
encountered. Process will terminate. Please call Xilinx support.
Problem Description:
map gives this error
FATAL_ERROR:basbd:basbdbool.c:393:1.5 - Signal unassigned to variable encounte
red. Process will terminate. Please call Xilinx support.
Solution 1:
This error has been fixed for version M1.4
This error can be patched by the following FTP files:
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_sun120897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_sol120897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_hp120897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_nt11.zip
End of Record #2863