Answers Database
How to ignore/remove LOC constraints on PADS?
Record #2898
Product Family: Software
Product Line: Merged Core
Problem Title:
How to ignore/remove LOC constraints on PADS?
Problem Description:
Keywords: LOC, constraints, PADS, ignore, 18471
Urgency: Standard
General Description:
LOC constraints defined in schematics are automatically passed to PAR by the
mapper, using the .pcf file.
Solution 1:
LOC constraints passed from the schematic can be modified or ignored
using the following options.
1. If ngdbuild is run with the "-r" switch, all location constraints
will be ignored. When using DM/FE, this switch can be added to the
flow by using the Template Manager to define a custom template.
2. The .pcf file can be modified with a text editor between mapping and PAR.
3. Location constraints can be modified by editing the design in EPIC. Select
and attibute individual components to modify their constraints. EPIC will
write the changes to the .pcf file when a save is performed.
End of Record #2898