Answers Database
Foundation Project Manager: Hierarchical, Error xr57 - Input signal drives more than one input buffer.
Record #2959
Product Family: Software
Product Line: Aldec
Problem Title:
Foundation Project Manager: Hierarchical, Error xr57 - Input signal
drives more than one input buffer.
Problem Description:
Keywords: Error, xr57, input, pad, buffer, ext
Urgency: Standard
General description:
Error xr57:
Input pad signal 'signalname' drives more than one input buffer.
A chip input can only drive 2 input signals when one drives a fast
input and the other drives a non-fast input. Make sure that two
input pad signals are not accidentally connected together.
Solution 1:
A possible cause may be that a lower level (NON-TOP LEVEL)
schematic is referred to in the Foundation Project Manager.
Additional EXT records are referenced by this lower sheet, thus
causing for the above mentioned error message.
In the Foundation Project Manager, the following should appear:
DESIGN.PDF
*DESIGN.UCF
*TOP_LEVEL.SCH
*DESIGN
*SIMPRIMS
*XC4000E
If any underlying sheets are listed here that are NON
TOP-LEVEL sheets, remove them by highlighting and going to :
Document-> Remove
Now re-run Design Manager by clicking on the XACT-M1 icon.
End of Record #2959