Answers Database
Design Manager M1.4: Place & Route Effort Level in Place & Route TAB remains unchanged
Record #2972
Product Family: Software
Product Line: FPGA Core
Problem Title:
Design Manager M1.4: Place & Route Effort Level in Place & Route TAB
remains unchanged
Problem Description:
Keywords: Place & Route tab, sliding knob, slider, template
Urgency: standard
General Description:
If you change the Place & Route Effort Level via its slider setting in the
Place & Route TAB of the Edit Implementation Template, go to another TAB
in the same template and then come back to the Place & Route TAB once again,
you will find that your Effort Level setting has reverted back to its
the default value.
Solution 1:
This is a bug within Design Manager(ver 1.4)
Whenever the Place & Route TAB is entered, the settings of the Place &
Route Effort Level slider are reset to whatever the value was when
the Edit Template was first entered into.
Workarounds:
1. Immediately after changing the value in the Place & Route TAB, click
on OK. The correct value will now be saved.
2. After having made modifications to the Place & Route TAB, do not
return to it again. Go to other TABs without coming back to the
Place & Route TAB, then select the OK button.
This issue has been fixed for the next release.
End of Record #2972