Answers Database
Hardware Debugger M1.4: Readback Capture displays wrong data.
Record #3068
Product Family: Software
Product Line: M1 Graphical/General
Problem Title:
Hardware Debugger M1.4: Readback Capture displays wrong data.
Problem Description:
Keywords: hardware, debugger, read, back, capture
Urgency: Standard
General Description:
The Hardware Debugger cannot perform a ReadCapture on any device
larger than an xc4013E or xc4010XL. No messages are issued, but
data displayed in the waveform window is erroneous and
unchanging.
Solution 1:
Xchecker Cable does not support the ammount of readback data required for device
s larger than the XC4013E. The next generation Xilinx Cable Product currently u
nder development will add this support. Targeted for M2.1 late 1998.
End of Record #3068
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |