Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


M1.4 CPLD: A fitter crash may result from properties applied to wrong objects


Record #3126

Problem Title:
M1.4 CPLD: A fitter crash may result from properties applied to wrong
objects



Problem Description:
Keywords: crash, fitter, properties, attribute, collapse, init,
keep, noreduce, pwr_mode, wireand

Urgency: standard

General Description:
The CPLD fitter may crash due to design properties being assigned
to the wrong type of objects.


Solution 1:

If the CPLD fitter program hitop crashes, check to see if there is
any I/O buffer, pad or pad-net in your design that has a property
attached to it that is intended only for macrocell-type objects.

The macrocell-only type properties are COLLAPSE, INIT, KEEP,
NOREDUCE, PWR_MODE and WIREAND. Using any of these properties on
an I/O object should normally produce an error or warning message.

Remove any such properties from the I/O objects and attach them to
the applicable macrocell objects (logic or flip-flop components),
and rerun the fitter.



End of Record #3126

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents