Answers Database
M1.4 GUI: 'Optimize & Map' tab for 5k implementation template has an incorrect option
Record #3135
Product Family: Software
Product Line: FPGA Core
Problem Title:
M1.4 GUI: 'Optimize & Map' tab for 5k implementation template has an
incorrect option
Problem Description:
Keywords: optimize & map, pack i/o registers/latches into iobs for,
xc5200, map options
Urgency: Standard
General Description:
MAP errors out if the value for the 'Pack I/O Registers/Latches into
IOBs for:' option in the Map Options box of the XC5200 Implementation
Template's Optimize & Map TAB is anything other than OFF.
Solution 1:
This option is invalid for the XC5200 devices and MAP will error
out if any other value is selected. Turn this option off and rerun
MAP.
End of Record #3135
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |