M1.4 GUI: 'Optimize & Map' tab for 5k implementation template has an incorrect option


Record #3135

Product Family:  Software

Product Line:  FPGA Core

Problem Title:
M1.4 GUI: 'Optimize & Map' tab for 5k implementation template has an
incorrect option



Problem Description:
Keywords: optimize & map, pack i/o registers/latches into iobs for,
xc5200, map options

Urgency: Standard

General Description:
MAP errors out if the value for the 'Pack I/O Registers/Latches into
IOBs for:' option in the Map Options box of the XC5200 Implementation
Template's Optimize & Map TAB is anything other than OFF.




Solution 1:

This option is invalid for the XC5200 devices and MAP will error
out if any other value is selected. Turn this option off and rerun
MAP.



End of Record #3135