Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


PAR: Error: baspw: 134 Input design is empty.


Record #3157

Product Family:  Software

Product Line:  Merged Core

Problem Title:
PAR: Error: baspw: 134 Input design is empty.


Problem Description:
While running the implementation flow you get the following error
just after PAR runs.

Error: baspw: 134 Input design is empty.


Solution 1:

In some cases map will trim all the logic out of the design
creating an empty .ncd file.  There is one very common and simple
cause for this problem.  This is due to some logic not being
connected in the schematic via IBUF's, OBUF's, IPAD's, and OPAD's.
Map will even trim out logic that has a input connection but no
output connection.  So in this case check the schematic and/or map
reports to see what is getting trimed out by map.



End of Record #3157

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents