![]() | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Record #3200 Problem Title: DRC needs to check for the shared EC/O wire used with ECMUX:0 Problem Description: The IOB EC pin shares its' connectivity with the O pin mux. If the ECMUX is configured as ECMUX:0, then the O pin can not use the shared part of the external pin routing. This is because the 0 is actually fed in through this resource. Solution 1: A DRC patch is available to add a check for conflicting EC/O wire configuration. This fix is available on the M1.3 Performance Pack CD and is also bundled into the latest map patch available on the FTP site: ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_sun120897.tar.Zftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_sol120897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_hp120897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/map_nt11.zip
End of Record #3200
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |
© 1998 Xilinx, Inc. All rights reserved Trademarks and Patents |