Answers Database
XC9500: How to program mulitple devices in a single chain using the HP3070 tester?
Record #3255
Product Family: Hardware
Product Line: 9500
Problem Title:
XC9500: How to program mulitple devices in a single chain using the
HP3070 tester?
Problem Description:
Keywords: hp, 3070, tester, svf, single, chain, multiple, eztag, svf2vcl, vcl, p
cf
Urgency: Standard
General Description:
The currently available software for the HP3070 Tester does not support mulitple
devices in
a single chain. Use the following procedure as a work-around
Solution 1:
Add connections from the TDO pin on each device to a tester pin. Regenerate the
SVF
files for each part as follows:
For Example, if you have 3 devices in the chain, let's call them A, B and C. Let
's say that A is
closest to the system TDI pin and C closest to the system TDO pin.
1. Generate the SVF file for C specifying a boundary-scan chain of 3 devices: A,
B and C,
2. Generate the SVF file for B specifying a boundary-scan chain of 2 devices: A
and B
3. Generate the SVF file for A specifying a boundary-scan chain of 1 devices: A
You should NOT concatenate the SVF files together because the TDO sense pin wil
l be
different for each SVF file.
4. Run each SVF file through the translator to generate the associate VCL/PCF fi
les.
5. Take these VCL/PCF files and compile them into an HP executable.
Run each executable under control of your testplan file as you would any normal
test
operation.
End of Record #3255