Answers Database
Foundation Simulator: End of time error
Record #3409
Product Family: Software
Product Line: Aldec
Problem Title:
Foundation Simulator: End of time error
Problem Description:
Keywords: End of time, Foundation, simulator, precision
Urgency: Standard
General Description:
Aldec uses a 32 bit integer to track the number of clock
periods. This results in approximately four billion clock
periods that can be tracked. When this integer overflows, an
'End of time error' is reported.
Solution 1:
This error can be fixed by changing the 'Simulation Precision'.
This can be done with the following steps:
* In the Logic Simulator, select Options->Preferences.
* In the tab section 'Simulation', change the 'Simulation
Precision' to a larger number. Click on 'OK'.
The design can now be simulated.
End of Record #3409
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |