Answers Database
Foundation Simulator, Logiblox, F1.4: Async_Val not simulated at power-up or GSR.
Record #3540
Product Family: Software
Product Line: Aldec
Problem Title:
Foundation Simulator, Logiblox, F1.4: Async_Val not simulated at
power-up or GSR.
Problem Description:
Keywords: Foundation, Logiblox, Simulation, Async_Val, powerup
GSR
Urgency: Standard
General Description:
While simulating a Logiblox counter (functional or timing) with
Async_Val defined, the Async_Val value is not output at
power-up or upon assertion of the Global Set/Reset. Instead, the output of the c
ounter is 0.
Solution 1:
Currently, the only way to simulate the power-up value of
Async_Val is to apply a logic 1 to the Async_Val pin of the
Logiblox counter.
Although the Async_Val value is not correctly displayed by the
simulator on power-up, it is correctly implemented in the
device. This can be verified in EPIC.
End of Record #3540