Answers Database
M1.4 : Dynatext gives Dynatext 3.0 Config Error 5055
Record #3575
Product Family: Software
Product Line: Other
Problem Title:
M1.4 : Dynatext gives Dynatext 3.0 Config Error 5055
Problem Description:
Keywords: Documentation CD, dtext, dynatext, dynatext.ini, DATA_DIR, Config Erro
r 5055,
Urgency: standard
General Description
After installing Dynatext Documentation to run from CD-ROM drive on a PC windows
95, and you have the installer update your Xilinx variable, you may get followin
g error when involking Dynatex Browser:
DTEXT : dytext 3.0 config error 5055
error in file d:\bin\nt\dynatext.ini
The data directory d:\\data\ntdtext\data cannot be located please verify data_di
r settings.
(in this case d: is the CD-ROM drive)
The problem is when M1.4 Implementation tool has not been installed on to the PC
, the installer will create the XILINX variable and set it to "XILINX=D:\". The
"\" at the end of this setting will conflict with some of the settings in the d
ynatext.ini file.
Solution 1:
Check XILINX variable setting in your AUTOEXEC.BAT file. If
you have: XILINX=D:\
change to: XILINX=D:
Remove "\", save your autoexec.bat, then re-boot your machine.
Then try involking Dynatext.
End of Record #3575
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |