Answers Database
Flow Engine M1: Error in reading flow definition file; unable to continue
Record #3669
Problem Title:
Flow Engine M1: Error in reading flow definition file; unable to
continue
Problem Description:
Keywords: flow engine, design manager, flow definition file
Urgency: Standard
General Description:
In attempting to start the Flow Engine, the implementation
tool returns a dialog box titled "Flow Engine", which
contains the following:
Error in reading flow definition file; unable to continue
Selecting the OK button returns one of the following:
This program has performed an illegal operation and will be shut down.
If the problem persists, contact the program vendor.
or
Dr. Watson for Windows NT (application error)
Solution 1:
Each device (xc3000, xc4000, etc..) contains a corresponding data directory,
within which an appropriate flow definition file (flow.dfn) is found.
i.e: $XILINX/xc3000/data/flow.dfn
$XILINX/xc4000/data/flow.dfn ...
The above mentioned message occurs if the flow.dfn file is
not found for the respective family, or has been corrupted in some way.
Replace missing/corrupted files with those found on the Design Implementation To
ols CD.
1. Search for all *.dfn files on the Design Implementation CD
2. Copy each flow.dfn file into its respective
$XILINX/<device>/data directory
3. Re-start implementation
End of Record #3669
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |