Answers Database
M1.4 Hitop - hitop error: Error:rg119
Record #3732
Product Family: Software
Product Line: CPLD Implementation
Problem Title:
M1.4 Hitop - hitop error: Error:rg119
Problem Description:
Hitop may fail on designs with lots of heirarchy that have
long signal and instance names. The error is:
hitop error: Error:rg119
Solution 1:
A fix is available on the Xilinx download area that truncates
signals to 80 characters. A long term fix that requires no
truncation is planned for M2.1 (release after M1.5).
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_sol9_m14.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_sun9_m14.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_hp9_m14.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/cpld_nt9_m14.zip
These update files also include the changes from previous cpld updates.
All zip files are created using WinZip. To obtain this utility,
access WinZip's web site at http://www.winzip.com
End of Record #3732
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |