Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


When using Turns Engine, you are unable to nice the PARs that are spawned off


Record #3734

Product Family:  Software

Product Line:  Merged Core

Problem Title:
When using Turns Engine, you are unable to nice the PARs that are
spawned off



Problem Description:
Keywords:  turns engine, par, nice

Urgency: Standard

General Description:
Trying to nice the nice the different PARs that are spawned will not work.  It w
ill still run PAR, but you can't specify the nice of the PAR process.


Solution 1:

Manually run the different PARs on the nodes specifying the nice.

nice +9 par ......

CR #104535 has been filed



End of Record #3734

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents