M1.5 9500/XL: (basts:158) Incorrect Warnings - CPLD Fitter does not support the TNM_NET property
Record #4101
Product Family: Software
Product Line: CPLD Implementation
Problem Title:
M1.5 9500/XL: (basts:158) Incorrect Warnings - CPLD Fitter does not
support the TNM_NET property
Problem Description:
Keywords: CPLD, Fitter, 9500, M1.5, TNM, property
Urgency: Standard
The TNM property (not TNM_NET) should be used to define timing
group names, as needed, for all types of timing constraints in a CPLD design, in
cluding PERIOD timespecs. When translating a CPLD
design containing PERIOD timespecs, please ignore the warning
during the NGDBuild step (basts:158) which recommends using
TNM_NET. Please continue to use the TNM property instead of
TNM_NET for CPLD designs when using Version 1.5 software.
Solution 1:
CR 105539.
End of Record #4101