M1.5 9500/XL: (basts:158) Incorrect Warnings - CPLD Fitter does not support the TNM_NET property


Record #4101

Product Family:  Software

Product Line:  CPLD Implementation

Problem Title:
M1.5 9500/XL: (basts:158) Incorrect Warnings - CPLD Fitter does not
support the TNM_NET property



Problem Description:
Keywords:  CPLD, Fitter, 9500, M1.5, TNM, property

Urgency:   Standard

The TNM property (not TNM_NET) should be used to define timing
group names, as needed, for all types of timing constraints in a CPLD design, in
cluding PERIOD timespecs. When translating a CPLD
design containing PERIOD timespecs, please ignore the warning
during the NGDBuild step (basts:158) which recommends using
TNM_NET. Please continue to use the TNM property instead of
TNM_NET for CPLD designs when using Version 1.5 software.


Solution 1:

CR 105539.



End of Record #4101