TEST DESCRIPTION | 
 Mil-Std-883 / JEDEC/STACK  | 
 | 
 | 
 | 
 | 
 | 
||
| 
 | 
PACKAGE/PROCESS | 
 | 
 | 
 | 
|||||
| 
 | 
Solder Heat Test (Optional) | 
 | 
 RTP0024  | 
Immersion in solder @ 260 °C for 12 sec 
 End-point electrical parameter @ 25 °C  | 
 | 
 | 
|||
| 
 | 
Resistance to Solvents | 
 | 
 | 
1 device per chemical for 1 minute, then brush 10 times | 
 | 
 | 
|||
| 
 | 
Solderability Test | 
 | 
 RTP0024  | 
8 hrs steam age: TH: 245 °C / 5 sec 
 SMC: 215 °C for 5 sec (wetting) SMC: 260 °C for 10 sec (dewetting)  | 
 (3 units)  | 
 | 
 | 
||
| 
 | 
Die Shear / Stud Pull | 
 | 
 | 
Die Shear strength > 5.0 kg | 
 | 
 | 
 | 
||
| 
 | 
Bond Pull | 
 | 
 | 
Bond Pull strength > 2 gm | 
 (4 units)  | 
 | 
 | 
||
| 
 | 
External Visual | 
 | 
 | 
Package defects, Lead defects | 
 | 
 | 
 | 
||
| 
 | 
Internal Visual | 
 | 
 | 
Die defects, die-attach defects and wirebond defects | 
 | 
 | 
 | 
||
| 
 | 
Lead Material/Plating
 Thickness (Optional)  | 
 | 
|||||||
| 
 | 
Process Cross-Section | Cross-Section shall be performed by the fabrication facility or by the Xilinx Process Technology Department. For Qualification: all layers are shown with measurements. For Monitors: vias, contacts and metal step coverage measurements are required. | 
 | 
||||||
| 
 | 
MICRO CIRCUIT FAMILY | ||||||||
| 
 | 
High Temp Life Test | 
 | 
 | 
125 °C / 168, 500 and 1000 hrs or equivalent 
 End-point electrical test @ 25 °C, verify device parameter drift (<10%)  | 
 | 
 | 
 | 
 | 
 #5, #8  | 
| 
 | 
Low Temp Life Test | 
 | 
 | 
< -10 ° C/1000 hrs 
 End-point electrical test @ 25 °C, verify device parameter drift (<10%)  | 
 | 
 | 
 | 
||
| 
 | 
ESD (HBM) | 
 | 
 RTP0032  | 
3 positive and 3 negative pulses, all pins tested, 2000 volts min. | 
 | 
 | 
|||
| 
 | 
High Temp Storage
 (Optional)  | 
 | 
 | 
150 °C / 500, 1000 hrs 
 End-point electrical test @ 25 °C  | 
 | 
 | 
|||
| 
 | 
PACKAGE DESIGN | ||||||||
| 
 | 
Physical Dimension | 
 | 
 | 
Per applicable package outline drawing 
 
  | 
 | 
 | 
 | 
||
| 
 | 
Lead Integrity 
 Seal (Fine/Gross)  | 
 Mil-Std-883 Mtd 2028 Mil-Std-883 Mtd 1014  | 
 B1064 B1024  | 
Condition B2 (Use Condition B1 for leaded
chip carrier pkgs 
 Condition A, Tracer gas (He) fine leak & Condition C, Perfluorocarbon gross leak  | 
 (3 units)  | 
 | 
 #7, #8  | 
||
| 
 | 
Thermal Shock + 
 Temp Cycle + Moisture Resistance Seal (Fine/Gross)  | 
 Mil-Std-883 Mtd 1010 Mil-Std-883 Mtd 1004 Mil-Std-883 Mtd 1014  | 
 B1002 B1049 B1005  | 
Condition C, -65/150 °C (Liquid to Liquid),
15 cycles 
 Condition C, -65/150 °C (Air to Air), 100 cycles 90% RH/ -10/25/65 °C, 10 cycles Condition A, Tracer gas (He) fine leak & Condition C, Perfluorocarbon gross leak  | 
 | 
 | 
 #9  | 
||
| Visual Examination | 
 | 
 B1007  | 
Per visual criteria in Method 1011 and Method
1004 
 End-point electrical Test @ 25 °C  | 
||||||
| 
 | 
Mechanical Shock + 
 Variable Frequency Vibration + Constant Acceleration Seal (Fine/Gross)  | 
 Mil-Std-883 Mtd 2007 Mil-Std-883 Mtd 2001 Mil-Std-883 Mtd 1014  | 
 B1076 B1008 B1005  | 
Condition B, 1500 G Peak, 0.5 msec pulse duration 
 Condition A, at peak acceleration of 20 g Condition E - For Pkg < 5 gms or inner sealed cavity < 2 inches Condition D - For Pkg >= 5 gms or inner sealed cavity >= 2 inches Condition A, Tracer gas (He) fine leak &  | 
 | 
 
 1x / 6 months  | 
 | 
||
| Visual Examination | 
 | 
 B1007  | 
Condition C, Perfluorocarbon gross leak 
 Per visual criteria in Method 1011 and Method 1004 End-point electrical test @ 25 °C  | 
||||||
| 
 | 
Salt Atmosphere 
 Visual Examination Seal (Fine/Gross)  | 
 Mil-Std-883 Mtd 1009 Mil-Std 883 Mtd 1014  | 
 B1027 B1005 B1006  | 
Condition A, soak time = 24 hrs 
 Per visual criteria in method 1009 Condition A, Tracer gas (He) fine leak & Condition C, Perfluorocarbon gross leak  | 
 | 
 | 
|||
| 
 | 
Internal Vapor Content | 
 | 
 | 
5000 ppm max. at 100 °C | 
 | 
 | 
 #11  | 
||
| 
 | 
Adhesion of Lead Finish
 (Optional)  | 
 | 
 | 
Bend Coated lead at an angle of 90° until
fracture occurs. 
 No flaking, peeling or detachment of coating at the interface.  | 
 | 
 | 
|||
| 
 | 
Lid Torque | 
 | 
 | 
Applicable to Glass Frit Sealed Package only 
 The Torque value must meet the minimum limits as specified in Table #1 of the Mil-Std-883 Method 2024.2  | 
 | 
 | 
 | 
||
| 
 | 
Temp Cycle 
 Seal (Fine/Gross)  | 
 Mil-Std-883 Mtd 1014  | 
 B1005 B1006  | 
Condition C -65/150 °C, 500 cycles 
 Condition A, Tracer gas (he) fine leak & Condition C, Perfluorocarbon gross leak End-point electrical test @ 25 °C  | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
ELECTRICAL ENDURANCE/EVALUATION & PROCESS VALIDATION DATA | ||||||||
| 
 | 
Electrical Test
 & Datalog  | 
 | 
@ 25 °C, Top min. & Top max. | 
 | 
 | 
||||
| 
 | 
Electrical
 Characterization  | 
 | 
Schmoo plot & Temperature trends for critical parameters | 
 | 
 | 
||||
| 
 | 
T.D.D.B. | 
 | 
Characterization of oxide integrity | 
 | 
 | 
 | 
|||
| 
 | 
Latch-Up | 
 | 
 | 
a) Immunity to PSOV of 20% over absolute Maximum
voltage 
 b) Immunity to +/-200mA current injection into I/O pins  | 
 | 
 | 
|||
| 
 | 
Electromigration | 
 | 
Characterization of Metallisation system 
 > 100,000 hours for 0.1% cumulative failures > 100,000 hours for 50% cumulative failures  | 
 | 
 | 
 | 
|||
| 
 | 
Photosensitivity
 (Optional)  | 
 | 
Apply 25W neon bulb, distance = 50 cm during electrical test. | 
 | 
|||||
| 
 | 
Data Retention Bake | 
 | 
 | 
Write device with suitable pattern, bake @
150 °C for 1000 hrs 
 Read and confirm data pattern End-point electrical test @ 25 °C  | 
 | 
 | 
 | 
||
| 
 | 
Input/Output
 Capacitance  | 
 | 
 | 
Biased @ nominal operating voltage | 
 | 
 | 
|||
| 
 | 
Power Cycling | 
 | 
5000 cycles @ 50 °C with Vcc = 5.0V 
 Vpp = 12 to 12.5 V  | 
 | 
 | 
||||
Notes:
| 
 1) 
 | 
For any Qualification or Product Monitor where sample size does not meet the Standard Quality level, approval from Product Engineering and Product QA is required. | 
| 2) | The Product Monitor Frequency applies to each package family with assembly locations and package type rotated each Quarter (when applicable). If only one package type exists within a package family, the product monitor frequency will be 1x / 12 months, minimum. | 
| 3) | The Product Monitor Frequency applies to each Micro Circuit Family. Plastic monitor data may be used to satisfy this requirement. | 
| 4) | End-point electrical test shall be performed within 48 hrs window. | 
| 5) | Interim read point is optional. | 
| 6) | The sample size is for numbers of bonds or numbers of leads. | 
| 7) | For LCC packages, use LTPD 15, 15 (0,1). | 
| 8) | Military QCI monitor data may be used to satisfy this requirement. | 
| 9) | End-point electrical test @ 25 °C shall be performed within 48 hrs after moisture resistance test. | 
| 10) | T.D.D.B. - Time Dependent Dielectric Breakdown | 
| 11) | In process monitor data may be used to satisfy the Qualification requirement; refer to Assembly Qualification lot traveller or Fab monitor data. | 
| 12) | Not applicable to FPGA's; H.T.O.L. test data @ 150 +0/-5 °C may be used to satisfy this requirement. |