Answers Database
 
 
 TAENGINE M1.3: ERROR:hi402 there is no original clock signal to clock pin *.CLKF 
 
 Record #3142
Product Family:  Software 
 
Product Line:  CPLD Implementation 
 
Product Part:  taengine 
 
Product Version:  1.3 
 
Problem Title: 
TAENGINE M1.3: ERROR:hi402 there is no original clock signal to clock pin *.CLKF  
 
 
Problem Description: 
Urgency:  standard 
 
General Description: 
 
Customer has a cpld design that they want to produce timing sim data for.  In m1.3 the design will t
ranslate and fit with no problems.  But then the taengine is executed and right away the flow engine 
  stops and the design manager will report that the deign was timed with errors.  If you open the tim 
ing report it is blank.  The last line of the fe.log is  : 
 
taengine -f design -l design.tim 
 
 
Solution 1: 
 
This error has been found in the M13.7 release with all the latest patches, however the problem has
been fixed in the M1.4 
release. 
 
 
 
 End of Record #3142 - Last Modified: 03/09/98 14:59  |