Answers Database
 
 
 M1.3/M1.4:  Hitop hangs for 9500 design 
 
 Record #3720
Product Family:  Software 
 
Product Line:  CPLD Implementation 
 
Product Part:  hitop 
 
Product Version:  1.3 
 
Problem Title: 
M1.3/M1.4:  Hitop hangs for 9500 design  
 
 
Problem Description: 
Keywork:  hitop, hang 
 
Urgency:  HOT 
 
General Description: 
When implementing the design through it hangs during the following command:  hitop -f ../xc9500.ngd 
-d design -s -l design.log -o design 
 
CR 103225 
 
 
Solution 1: 
 
Resolution: 
 
For M1.3 - 
There is no resolution other than upgrading to M1.4 
 
For M1.4 - 
Turn on the switch for Multi-Level Logic Optimization in the Implementation Option Template (this is 
  usually on by default) 
 
NOTE:  This is fixed in M1.5, where you don't need to turn on MULTI_LEVEL_LOGIC_OPT to get hitop to
complete, but you will still need it to get it to fit. 
 
 
 
 End of Record #3720 - Last Modified: 04/02/98 18:29  |