Answers Database
 
 
 2.1i:  Constraints Editor - TIMESPEC TSxx = FROM(abc) TO(xyz) - WARNING : Unable to create FROM TO with tsxx 
 
 Record #6383
Product Family:  Software 
 
Product Line:  M1 Implementation 
 
Product Part:  Constraints Editor 
 
Product Version:  2.1i 
 
Problem Title:
  
2.1i:  Constraints Editor - TIMESPEC TSxx = FROM(abc) TO(xyz) - WARNING : Unable to create
FROM TO with tsxx 
 
 
 
Problem Description: 
Urgency: Standard 
 
General Description: 
A following timespec definitation is not understood by 
Constraints Editor. 
      timespec ts05 = from pads(pclk) to ffs  = 6 ns; 
 
Generates warning: 
WARNING : Unable to create FROM TO with ts05. 
 
 
Solution 1: 
 
The warning can be ignored or the user can modify the ucf 
file to include the timegrp and then the timespec. 
 
For example: 
    timegrp pad_pclk = pads(pclk); 
    timespec ts05 = from pad_pclk to ffs = 6ns; 
 
This will be fixed in a future release of the software. 
 
 
 
 End of Record #6383 - Last Modified: 06/28/99 09:41  |