Record #1183 Product Family: Software Product Line: ViewLogic Problem Title: Proflow : Project Verification Error Problem Description: Upon entering Proflow you may get the following error message : Stop : Project Verfication Error: Proflow will then display the environment data and shut down. Solution 1: One cause of this problem is when the current project number is too large in the project.lst file. The number on the first line of this file must be at least one number less than the total number of directories listed in the file. Open the <proser>/standard/vf/project.lst and change this number to 0 so that it will now point to the first directory. A sample project.lst file look like the following : 2 <----- Try changing this number to 0 c:\designs\mydesign c:\others\urdesign c:\demos\pci End of Record #1183