PLC003: No legal global assignment could be found because of complex region and/or I/O technology constraints.

Automatic global net placement cannot find a legal assignment because region and I/O constraints make finding an assignment impossible.

Action

Use PDC or the MultiView Navigator tools to relax the region and/or I/O constraints.