Power-up state

Purpose: Indicates the power-up state of the pin. All I/Os are equipped with pull-up and pull-down resistors, which are enabled during power-up. These resistors are disabled just before VCCA reaches 2.5V, and then the I/Os behave according to the design. For eX and SX-A, this configurable I/O state does not eliminate the risk of an I/O driving a temporary unknown state near the end of the power-up sequence when VCCI is powered up before VCCA. For RTSX-S, the outputs will drive according to the design, when the resistors become disabled regardless of the power-up sequence.

Families

Supported

Fusion

No

ProASIC3E

No

ProASIC3

No

ProASIC PLUS

No

Axcelerator

No

ProASIC

No

SX-A

Yes

SX

No

RTSX-S

Yes

eX

Yes

MX

No

 

Values: Use this attribute to set the power-up state. Your choices are None, High, and Low.

 