HW-130: 7372 is non-functional if security bit is programmed


Record #1004

Product Family:  Hardware

Product Line:  Programmers

Problem Title:
HW-130:	7372 is non-functional if security bit is programmed


Problem Description:
There was a known problem in revision 2.03 of the HW-130 software (v1.06
of the 7372 algorithm) in which programmed 7372 devices did not work  if the
security bit was programmed.  This was fixed in version 2.04 of hw130, which
was made available on the Xilinx BBS at the end of March 1996.


Solution 1:

Download the latest version, v2.04, of the hw130 program from the BBS.	This
archive includes the fixed 7372 algorithm, v1.07.