Answers Database


Obsolete -- Orcad SDT2XNF, INF2XNF ERROR 1, internal program error, code 0, return code 3


Record #294

Product Family: Software

Product Line: OrCAD

Product Part: sdt2xnf

Product Version: 5.0

Problem Title:
Obsolete -- Orcad SDT2XNF, INF2XNF ERROR 1, internal program error, code 0, return code 3


Problem Description:
Customers using XEPLD v5.0 tools with the old libraries could receive the
following error from sdt2xnf:

INF2XNF: Fatal Error:
----------------------------------------------
DS35-SDT-ERROR-001:
An internal program error occurred, code '0'.
----------------------------------------------
...
Return code from 'inf2xnf <parameters>' = 3



Solution 1:

This is due to an error in the library files for the PLOUT8A component.
Use individual PLOUTT components instead of PLOUT8A.






End of Record #294 - Last Modified: 04/30/99 16:13

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!