Answers Database
XACT 5.0 memory manager requirements for all products
Record #373
Problem Title:
XACT 5.0 memory manager requirements for all products
Problem Description:
Solution 1:
These are the memory manager requirements for the Virgil software:
1) XACT 5.0, including all third party interface programs and Xabel:
None required. Works with any memory manager that provides XMS, VCPI,
or DPMI standards. The only memory managers we have tested are
Microsoft HIMEM and Quarterdeck QEMM386.
2) OrCAD 386+ v1.10 (the version we support):
Same as 1) above.
3) Workview 4.1.3a (the version we OEM):
None required. On the contrary to Viewlogic's app note and our
recommendation to use QEMM in the past, theoretically it should NOT
behave correctly under any memory manager.
4) Microsoft Windows 3.1:
Requires HIMEM, QEMM386, or any other memory manager that provides XMS.
The only memory managers we have tested are Microsoft HIMEM and
Quarterdeck QEMM386.
5) Microsoft disk cache program SMARTDRV:
Same as 4) above.
Extra considerations:
- Workview works OK most of the time, when used under EMM386. It has been
known to crash the PC if XACT 5.0 is run after doing certain operations
in Workview however.
End of Record #373 - Last Modified: 10/30/97 16:11 |