XSIMMAKE 5.2, Viewlogic: Possible cause of ERROR 7
Record #392
Product Family: Software
Product Line: XACT FPGA
Product Part: xsimmake
Product Version: 5.2
Problem Title:
XSIMMAKE 5.2, Viewlogic: Possible cause of ERROR 7
Problem Description:
If a the top level name for a design has a dash in it, then XSimMake will fail with:
ERROR 7: [wir2xnf.exe -b -v -od ste-st\...] failed
to execute properly
Please check results in xsimmake.out
1 Errors and 0 Warnings occurred during processing.
Solution 1:
Change the desing name to one that doesn't have the dash.
Solution 2:
Ensure the sheet names are no longer than eight characters.