Answers Database
MEN2XNF8 5.x: Could not find a registered simulation model with label: 'xc____'
Record #547
Product Family: Software // Warning: Instance: '/RETARGETED/SYMBOL' // Could not find a registered simulation model with label: 'xc3000' // NULL model will be inserted. (from: Analysis/Digital Simulation Utilities/Dsim 85) ENWrite (Mentor's EDIF netlister) uses an XNF viewpoint to determine which device family it should target. Changing the library references in a design does nothing to its viewpoints, so the XNF viewpoint still reflects the old device family. However, the new library elements in the design expect to see a reference to the new device family; thus the warning message. Solution 1: Delete the XNF viewpoint, then run Men2XNF8 again. This time, Men2XNF8 will see that the viewpoint does not exist, and will recreate it for the correct library. For further instructions, see Solution 766, "How to delete a design viewpoint in Mentor." End of Record #547 - Last Modified: 05/24/99 11:45 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |