Answers Database


XNF2WIR returns error 201 if viewdraw.ini is not in project directory


Record #577

Product Family: Software

Product Line: ViewLogic

Product Part: xnf2wir

Product Version: 5.2

Problem Title:
XNF2WIR returns error 201 if viewdraw.ini is not in project directory


Problem Description:
XNF2WIR ERROR 201: Unable to open file viewdraw.ini for reading.
1 Errors and 0 Warnings occurred during processing.
Sorry, errors found, could not create output file.

XNF2WIR fails with this error, even though there is a viewdraw.ini in WDIR search path.


Solution 1:

XNF2WIR requires a local viewdraw.ini file, even though the PROseries tools
accept the viewdraw.ini file pointed to by the WDIR variable.

Include a viewdraw.ini file in your design directory.





End of Record #577 - Last Modified: 12/23/96 11:35