Answers Database


Error cl192 or cl126 while converting a PALASM (PDS) file


Record #671

Product Family: Software

Product Line: XACT EPLD

Product Part: palconvt

Problem Title:
Error cl192 or cl126 while converting a PALASM (PDS) file


Problem Description:
PALCONVT may issue one of the following errors while translating a
PALASM (.PDS) file:

cl192:[Error]Pin '<signal_name>' is not declared as an output pin !

cl126:[Error]The equation input '<signal_name>' is not declared !


Solution 1:

PALCONVT only supports PALASM v2.2 and earlier syntax.

Remove any PALASM v2.3 or later syntax from the PDS file. For example,
parentheses are not part of PALASM v2.2 or earlier.

A partial listing of unsupported PALASM syntax can be found in the
XEPLD Reference Guide, near the end of the "PLUSASM Command
Reference" chapter.




End of Record #671 - Last Modified: 01/22/96 10:43

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!