Answers Database
Design Manager: System Error, Unhandled Exception: ERROR_FILE_NOT_FOUND
Record #752
Product Family: Software 4) Start up the design manager. It should prompt you with this message>> Cannot read the project file: c:\xxx\xxxx\design.prj. The file is unreadable and may be corrup ted. Do you want to recover, using the project backup file? Answer with a Yes. Next Message>> Could not recover using the project backup file. Do you want to recreate the project information? Answer with a Yes. 5) Now a New Project screen will pop up and you will need to specify your top_level_design.1 This is where some problems occur. It may or may not let you choose a Target Family. (a)If it does choose the one you want, and everthing else should be okay (you should be able to t ranslate). (b)If it doesn't let you choose it will give you this error >> Cannot find data file ".bos" in the XACT path. If you get this press cancel. Then go to File -> New Project and specify your top_level_design.1 file You should now be able to translate and continue from there. Solution 3: Cause: The Xilinx software and/or the project directory are on a network drive. This problem has been observed on a Novell network v4.12. Solution: Move the project directory and/or Xilinx software from the network drive to a local drive. Solution 4: If the error still occurs, create a new Foundation project and import the design files from the corrupted project by selecting Document -> Add in the Foundation Project Manager. Next click on the XACT button. This will create a new netlist and a new Xilinx project End of Record #752 - Last Modified: 01/15/97 20:24 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |