Answers Database


ProCapture Error when printing : vlwp Metafile does not exist


Record #897

Product Family: Software

Product Line: ViewLogic

Product Part: PROcapture

Product Version: 6.1

Problem Title:
ProCapture Error when printing : vlwp Metafile does not exist


Problem Description:
When attempting to print a schematic in PROcapture 6.1
it returns the following popup dialog:

vlwp
<Stop> Metafile C:\<library directory>\<project directory>\
<schematic name> does not exist

This occurs when the first library listed in the viewdraw is not
the primary directory. PROcapture looks in first library pointed
to by the viewdraw.ini file and not in the primary directory.


Solution 1:

Edit the Viewdraw.ini so that the primary (project) directory
is the first library listed.




End of Record #897 - Last Modified: 04/26/96 12:02