Answers Database


PPR Error #1173 fplan.p file cannot be found when PPR is Run From FloorPlanner.


Record #906

Product Family: Software

Product Line: XACT FPGA

Product Part: ppr

Product Version: 5.2

Problem Title:
PPR Error #1173 fplan.p file cannot be found when PPR is Run From FloorPlanner.


Problem Description:
When processing a XC3000A design in the FloorPlanner using the Place command,
PPR reports that it can not find the fplan.p file.


Solution 1:

This problem is caused because the Place command is not supported by
PPR with XC3000A devices. This is because XNFMAP which produces the
fplan.p file does not produce the fplan.p file. You can either place the
design from the the Flow Engine after writing out a constraint file in the
FloorPlanner, or you can run the Place and Route command from the
FloorPlanner instead of just the Place command.




End of Record #906 - Last Modified: 10/10/96 18:24