Answers Database


PLD_Men2XNF8 5.x: "test: unknown operator"


Record #913

Product Family: Software

Product Line: Mentor

Product Part: men2xnf8

Product Version: 5.2

Problem Title:
PLD_Men2XNF8 5.x: "test: unknown operator"


Problem Description:
Urgency: Standard

General Description:

When running PLD_Men2XNF8 from PLD Design Manager in Mentor, the
translation halts with the message:

    test: unknown operator

(Running Men2XNF8 from the Unix command line, however, works fine.)


Solution 1:

This is caused by leading and/or trailing spaces in the Part Type field in
the PLD_Men2XNF8 dialog box. Delete these spaces and try again.




End of Record #913 - Last Modified: 05/24/99 11:36

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!