Answers Database
**Obsolete Solution**: Programmers: HW-130: The 7372 is non-functional if the security bit is programmed
Record #1004
Product Family: Hardware Urgency: Standard General Description: There was a known problem in revision 2.03 of the HW-130 software (v1.06 of the 7372 algorithm) in which programmed 7372 devices did not work if the security bit was programmed. This was fixed in version 2.04 of hw130, which was made available on the Xilinx BBS at the end of March 1996. Solution 1: Download the latest version, v2.04, of the hw130 program from the BBS. This archive includes the fixed 7372 algorithm, v1.07. End of Record #1004 - Last Modified: 07/30/99 14:09 |