Answers Database


BOUNDARY SCAN/JTAG: Timing Parameters (rise time, fall time, max frequency) for TMS,TCK, and TDI


Record #1188

Problem Title:
BOUNDARY SCAN/JTAG: Timing Parameters (rise time, fall time, max frequency) for TMS,TCK, and TDI



Problem Description:
Urgency: Standard

General Description:

Where is the TAP timing data for the Xilinx devices?


Solution 1:

Virtex specifications can be found at the end of the Switching
Characteristics Section of the 1999 databook.
http://support.xilinx.com/partinfo/virtex.pdf



Solution 2:

XC4000X, Spartan and Spartan XL, refer to
the XC4000E section of the databook. For the faster parts, this is a
conservative number.

XC4000E Boundary Scan (JTAG) Switching Characteristic Guidelines
are available in the latest 4000e datasheet on page 6-116.
http://www.xilinx.com/partinfo/4ke_ac.pdf


XC5200 TAP timing parameters are available on the web at
http://www.xilinx.com/partinfo/5200.pdf. The data is located in
the switching characteristics portion of the document.




End of Record #1188 - Last Modified: 09/01/99 14:40