Answers Database


PPR 5.2.x: abnormal program termination: memory protection fault in Windows95 (Win 95)


Record #1191

Product Family: Software

Product Line: XACT FPGA

Product Part: ppr

Product Version: 5.2

Problem Title:
PPR 5.2.x: abnormal program termination: memory protection fault in Windows95 (Win 95)


Problem Description:
In windows95, PPR might give you the following error when trying to route a design:

PPR: Abnormal program termination: memory protection fault


Solution 1:

For maximum DOS Memory in an MS-DOS session, add the line:

LocalLoadHigh=1

to the [386Enh] section of the system.ini file.



Solution 2:

There are a couple of things to try in this situation. One solution that worked for me is as follow s:

Force Windows95 to allocate memory for command.com

In windows95, click on My Computer. Open Ms-dos_6. Find the command.com icon and _right_ click on it. When the pop-up menu appears, click on properties. Next click on the memory tab in the propert ies window. Set the Extended(XMS) memory setting to 1024. Also be sure that "uses HMA" is checked.
   All other selections should be set to "auto". Click on apply and OK. Then reboot Win95 and try r
unning ppr again.




End of Record #1191 - Last Modified: 02/13/97 10:32