Answers Database


PACKAGES: Information on calculating Temperature/Thermal Characteristics (Theta-JA)


Record #1226

Product Family: Documentation

Product Line: Data Book

Product Part: Programmable Logic Data Book

Problem Title:
PACKAGES: Information on calculating Temperature/Thermal Characteristics (Theta-JA)


Problem Description:
Urgency: Standard

General Description:
This is a brief summary on determining the thermal characteristics of a Xilinx Part. A more detaile d discussion of thermal characterization can be found in the chapter called "Packages and Thermal Ch aracteristics"
usually located in the last sections of the data book.


Solution 1:

Theta-JA (junction-to-ambient heat resistance) is used to calculate the die temperature, which shoul d not exceed the maximum temperature rating for a particular device. Theta-JA is the increase in te mperature that a device will experience, relative to the ambient temperature, over the amount of pow er dissipated by the device (degrees Celsius per watt). In short, the following equation must hold:


    Ta + P*Theta-JA < Tj

where Ta is ambient temperature, P is the power dissipated by the device, and Tj is the maximum temp erature rating for the device (85C commercial, 100C industrial, Tc=125C for military).

We measure Theta-JA in four different situations:

     0 LPM (still air)
   250 LPM (air flow of 250 linear feet per minute)
   500 LPM (  "  "  "	500   "  "  "  "  "  "	" )
   750 LPM (  "  "  "	750   "  "  "  "  "  "	" )

You can therefore use the measurement or measurements that fit your particular situation.

Note: For most devices the temperature range for Military
grade devices (M and B) is the case temperature not the
junction temperature. For further information on a
partitcular device please check the Xilinx Programmable
Logic Databook.




End of Record #1226 - Last Modified: 03/02/98 11:37

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!