Answers Database
XC3000/XC4000/XC5200: PAR ERROR 4kpl:7 - Too many TBUFs (TRISTATEs) driving longline
Record #1312
Product Family: Software
| | | ...... |
\~~~/ \~~~/ \~~~/ \~~~/
--\ / --\ / --\ / --\ /
| | | |
========x=======x=======x=====================x======== horizontal
longline
The TBUFs in all FPGA architectures may access only the horizontal longlines, and each longline has a limited number of TBUFs that can access it. The number of TBUFs that may access a horizontal longline for a given part is listed in the Data Book. If PAR error 4kpl:7 is referencing TBUFs, then the problem is that you have exceeded the number of TBUFs that can drive a single longline. Solution 1: The following design hint may or may not be practical for your design. Divide up your TBUFs into two of more groups, each group driving its own node/line. Then, mux the resulting lines together, and develop control logic to drive the select line of the mux.
End of Record #1312 - Last Modified: 01/12/98 14:21 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |