Answers Database


Hardware debugger: Incorrect cable specification given.


Record #1322

Product Family: Software

Product Line: M1 Graphical/General

Product Part: Hardware Debugger

Problem Title:
Hardware debugger: Incorrect cable specification given.


Problem Description:
When Hard ware debugger is trying to establish communications with the xchecker cable and device it may return the message;

Incorrect cable specification given. The
connected cable is : Serial


Solution 1:

Something about the cable is recognized as 'Serial':

1) Make sure that the cable is an xchecker cable.
The head will say:

Model: DLC4
Power: 5V 100mA Typ.
Serial: DL <number>

2) Make sure that user specifies the correct port.

     For hwdebugr, use Setup->Commmunication to specify the correct port
     For xchecker, run it as: xchecker -port com2

3) Make sure that the cable is on the correct port

4) Check to see if the customer has mouse or other device
like a fax or modem connected to the serial port?








End of Record #1322 - Last Modified: 01/09/97 17:29