**Obsolete Solution**: Programmers: HW-130: PROLINK/HW-120: Manufacturer and product code / product i.d. errors on 7300 devices
Record #1415
Product Family: Hardware Urgency: Standard General Description: HW-130, PROLINK/HW-120: Manufacturer and product code / product i.d. errors on 7300 devices The HW-120 and HW-130 programmers may issue Manufacturer I.D. and Product I.D. errors on 7300 devices. Solution 1: If the failure is consistent over many devices, look for bent pins and shorts on the adapter. Solution 2: On the HW-120, this may also be due to use of an outdated algorithm. There have been at least 3 die revisions for the 7K and 1700/D parts, and the HW-120 only supported the first two. If an outdated algorithm is the problem, the customer should contact his/her distributor or sales rep to get upgraded to an HW-130. The HW-120 is no longer supported. End of Record #1415 - Last Modified: 07/30/99 19:06 |