Answers Database
**XACT-CPLD: Need two Project.lst files if using both XACT and XACT-CPLD and PROflow
Record #1504
Product Family: Software
Product Line: ViewLogic
Product Part: PROflow
Product Version: 3.0
Problem Title:
**XACT-CPLD: Need two Project.lst files if using both XACT and XACT-CPLD and PROflow
Problem Description:
Urgency: Standard
General Description:
After successfully FPGA implementating using ProSeries and Xact 6.0.1 and
then switching all the environment variables to refer to the XACT_CPLD tools,
ProFlow complains about an invalid or unreachable project.lst file.
Solution 1:
Apparently the only working solution is to have 2 separate project files:
one for FPGA Development (XACT) and one for CPLD Development (XACT-CPLD).
Copy the desired one to c:\proser\standard\vf\project.lst, depending on
which development tools you are using.
End of Record #1504 - Last Modified: 12/27/99 17:25 |