Answers Database


**Obsolete**Foundation 6.0 Install: Error: VXD driver Daikon.386 missing


Record #1512

Product Family: Software

Product Line: M1 Graphical/General

Product Part: Install

Product Version: 6.0

Problem Title:

**Obsolete**Foundation 6.0 Install: Error: VXD driver Daikon.386 missing


Problem Description:
When running Xact from Foundation Project Manager, this error comes up:

Error:	VXD driver Daikon.386 necessary to run this program has not
	been installed or is not running.


Solution 1:

Add this line in the c:\windows\system.ini file under the [386Enh] header.

device=daikon.386

Make sure this file exists in the c:\windows\system directory.
The file is found on the XACTstep 6.0 CD under XACT\Windows\System.




End of Record #1512 - Last Modified: 05/21/99 15:08