Answers Database
XACT-CPLD: rg37:[Warning] Programming output for device type 95144160 is not supported
Record #1594
Product Family: Hardware
Product Line: 9500
Product Part: 95144
Problem Title:
XACT-CPLD: rg37:[Warning] Programming output for device type 95144160 is not supported
Problem Description:
Using XACT-CPLD, the Design Manager may fail in the programming
file generation phase with the following error:
Programming File Generator Version XACT-CPLD-V6.0.2a
(c) Copyright 1989-1995 Xilinx Inc. All rights reserved.
Design Name: calc9k
rg37:[Warning] Programming output for device type 95144160
is not supported in this release.
You will notice that the JEDEC file produced will be empty(0 bytes).
Solution 1:
This message indicates that the data files necessary to create
the JEDEC file are not yet available, since the device being
targetted, XC95144, was not yet available when the software was
released.
Using Xact-cpld you had the option of targetting a 95144
to evaluate the fitting and timing characteristics of the
design. This way, when the part became available, the device could be
programmed with the design.
The M1.4 Xilinx software with patch (refer to solution record 4339), and M1.5 Xilinx software suppor
t this device 95144 jedec creation, this is
the newer version of our software. Please contact your Xilinx local sales
representative if you have any questions on our new software packages.
End of Record #1594 - Last Modified: 09/15/98 13:16 |