Answers Database
ViewDraw Symbols May Not Be Updated Properly After Entering a Change LogiBLOX Command
Record #1751
Problem Title:
ViewDraw Symbols May Not Be Updated Properly After Entering a Change LogiBLOX Command
Problem Description:
Platform(s): All
Architecture(s): All
Design Step(s): Design Entry with LogiBLOX
Reference Number: 9600
If you perform a Change LogiBLOX command in ViewDraw without
choosing a new module name, the updated symbol may not be
displayed properly in the ViewDraw schematic.
Solution 1:
If the size of the new symbol is different than that of the old one - typically the case when you ch
ange the basic type of a module - the selection outline will not be aligned with the graphical repre
sentation of the symbol. To correct this, save the schematic and choose the Read command from the Vi
ewDraw File menu to read it back in.
End of Record #1751 - Last Modified: 06/02/97 13:47 |