ViewDraw Symbols May Not Be Updated Properly After Entering a Change LogiBLOX Command


Record #1751

Problem Title:
ViewDraw Symbols May Not Be Updated Properly After Entering a Change LogiBLOX Command


Problem Description:
Platform(s): All
Architecture(s): All
Design Step(s): Design Entry with LogiBLOX
Reference Number: 9600
If you perform a Change LogiBLOX command in ViewDraw without
choosing a new module name, the updated symbol may not be
displayed properly in the ViewDraw schematic.


Solution 1:

If the size of the new symbol is different than that of the old one - typically the case when you ch ange the basic type of a module - the selection outline will not be aligned with the graphical repre sentation of the symbol. To correct this, save the schematic and choose the Read command from the Vi ewDraw File menu to read it back in.




End of Record #1751 - Last Modified: 06/02/97 13:47