Answers Database
ppi2040:[Error] The instance '$1I1/O' of component type 'OBUFT' is not supported or...
Record #1815
Product Family: Software
Product Line: XACT EPLD
Product Part: xemake
Product Version: 5.2
Problem Title:
ppi2040:[Error] The instance '$1I1/O' of component type 'OBUFT' is not supported or...
Problem Description:
When compiling an XC7000 design with the 5.2.0 EPLD software
tools (workstation only), the following error may be
encountered:
xemake 5.2.0
ppi2040:[Error] The instance '$1I1/O' of component type
'OBUFT' is not supported or the netlist was not generated with
the XC7000 library.
This is caused by errors in the xnf7000 library for version 5.2.0.
Solution 1:
The problem has been fixed in XACT v5.2.1.
Either upgrade to XACT v5.2.1, or replace the xnf7000 directory
with the files from the XACT v5.2.1 release.
End of Record #1815 - Last Modified: 02/04/97 16:39 |