Answers Database
Xc9500: The fitter report pinout does not match that of the data book
Record #1929
Product Family: Software Xc9500: The fitter report pinout does not match that of the data book Problem Description: Urgency: Standard General Description: After compiling a 9500 design, you may notice that the fitter report does not appear to match the expected pinout as stated in the Data Book, ie GNDs and VCCs may not be where the Data Book says they should be. XABEL CPLD v6.1.2 Solution 1: This can be caused by having more than one signal assigned to the same pin. The CPLD fitter will not give you a warning that you have assigned 2 signals to one pin. Check the source file for cases where more than one signal drive a pin or are assigned to a pin. End of Record #1929 - Last Modified: 05/23/97 17:27 |