Answers Database


Prowave: Can't load .wfm file into Prowave


Record #1959

Product Family: Software

Product Line: ViewLogic

Product Part: PROwave

Product Version: 6.1

Problem Title:
Prowave: Can't load .wfm file into Prowave


Problem Description:
Prowave: Can't load .wfm file into Prowave

Sometimes the .wfm file that Prosim creates is larger than the system can
handle. Here are three potential workarounds:


Solution 1:

   Reduce the number of monitored signals in the command (.cmd) file after
   the wave command to reduce the number of waveforms to be displayed.
   Make multiple command files that produce multiple .wfm files.

	<design1>.cmd	--->   <design1>.wfm
	<design2>.cmd	--->   <design2>.wfm
	<design3>.cmd	--->   <design3>.wfm
      ... etc.



Solution 2:

   If the first two suggestions are not possible, then the only remaining
   possibility is to upgrade the system memory to exceed the size of the
   .wfm file.



Solution 3:

   Break up the design into smaller time increments by simulating until known
   states occur, or use the assign statement to reduce the number of cycles
   necessary to set up signals.





End of Record #1959 - Last Modified: 02/27/97 16:18